ProductWiki.aiby PriceQ
GeneracAutomatic transfer switchRead on generac.comSearched on PriceQ

Automatic Transfer Switch 100 Amp

Last updated Nov 1, 2026 · 3 entries in Page history

Generac's RXG16EZA3 is a 100A automatic transfer switch with a 16 circuit panel board, expandable to 24 with tandem breakers at the bottom four positions, in a NEMA and UL 3R enclosure.

Part number or model
RXG16EZA3
Catalog number
Not assigned yet
No confirmed photo of this model

Specifications

16 fields, as the sources state them

Owner's manual

Model Number
RXG16EZA31
Automatic Transfer Switch
100 Amp1
Assembly Number When Bundled with Generator
100000120541
Introduction
This transfer switch is listed with ETL under the UL1008 standard.1
Contents in Loose Parts Bag
Owner’s manual Warranty statement Manual operating handle Storage bracket for manual operating handle Fault current label Clear decal for fault current label1
Equipment Description
The automatic transfer switch is used for transferring electrical load from a UTILITY (NORMAL) power source to a GENERATOR (STANDBY) power source. Such a transfer of electrical loads occurs automatically when the UTILITY power source has failed or is substantially reduced and the GENERATOR source voltage and frequency have reached an acceptable level. The transfer switch consists of a transfer mechanism and an integrated PCB.1
Transfer Switch Mechanism
These switches are used with a single-phase system when the single-phase NEUTRAL line is to be connected to a neutral lug and is not to be switched. Solderless, screw-type terminal lugs are standard. This transfer switch is suitable for control of motors, electric discharge lamps, tungsten filament and electric heating equipment where the sum of motor full load ampere ratings and the ampere ratings of other loads do not exceed the ampere rating of the switch and the tungsten load does not exceed 30 percent of the switch rating. This UL listed transfer switch is for use in optional standby systems only (NEC article 702). This transfer switch is suitable for use on a circuit capable of 10,000 (100A) symmetrical amperes, 240 VAC maximum.1
Switch Rating
100A1
Wire Range
#14-1/0 AWG (Cu/Al)1
Conductor Tightening Torque
50 in-lbs (5.6 Nm)1
Lug Temp. Rating
167°F (75°C)1
Utility Service Circuit Breaker (not supplied)
This switch is listed for use with the following one inch breakers: Siemens* Murray* Eaton Square D *Including GFCI, AFCI and tandem breakers up to 50 amps. NOTE: For branch circuits over 50 amps, only listed Siemens or Murray circuit breakers shall be used.1
Transfer Switch Enclosure
The standard switch enclosure is a National Electrical Manufacturer’s Association (NEMA) and UL 3R type. UL and NEMA 3R (indoor/outdoor rated) type enclosures primarily provide a degree of protection against falling rain and sleet; are undamaged by the formation of ice on the enclosure.1
Neutral and Ground Bars
Neutral and Ground Bars Accept #4-#14 AWG Cu/Al cable. If a larger Neutral or Ground Cable is required for the Generator Connection, Please utilize Lug Kit Siemens ECLK2 or Generac part number 10000006293 which accepts #4-2/O Cu/Al cable.1
Installation Drawing
764.3mm [30.1"] 341.8mm [13.5"] 175.4mm [6.91"] 679.45mm [26.75"] 266.7mm [10.5"] KNOCKOUT SUITABLE FOR 1-1/2" & 2" CONDUIT SIZE2

Interconnection diagram

16 CIRCUIT 3R TRANSFER SW
UL LISTED PANEL BOARD 16 CIRCUIT TRANSFER SWITCH EXPANDABLE TO 24 USING TANDEM BREAKERS AT BOTTOM FOUR POSITIONS3

Sources: generac.com, Owner's Manual, cover and pages 1, 5, 6 and 10, read Nov 1, 2026 UTC; generac.com, Owner's Manual, page 17, Installation Drawing No. 10000012171-A, read Nov 1, 2026 UTC; productmanuals.generac.com, Interconnection diagram, drawing 10000016945, sheet 1 of 2, read Nov 1, 2026 UTC.

Size and weight

Inches and pounds, millimetres and kilograms

The product

WhatInches and poundsMillimetres and kilograms
Dimensions30.1×13.5×6.91 in764.3×341.8×175.4 mm

Figures in black are the maker’s. Figures in grey are converted by the wiki (1 in = 25.4 mm, 1 lb = 0.45359237 kg).

Compare with

1 of the same family on the wiki

More from Generac

6 pages on the wiki

All 6 Generac pages →

Documents

6 linked, none copied here

References

5 sources, each with the day it was read

  1. generac.com, Owner's Manual, cover and pages 1, 5, 6 and 10, read Nov 1, 2026 UTC. Supports 14 specifications, the related products, the documents
  2. generac.com, Owner's Manual, page 17, Installation Drawing No. 10000012171-A, read Nov 1, 2026 UTC. Supports 1 specification
  3. productmanuals.generac.com, Interconnection diagram, drawing 10000016945, sheet 1 of 2, read Nov 1, 2026 UTC. Supports 1 specification, the documents
  4. generac.com, generac.com's address for this model, which now redirects to the G0099470 page, read Nov 1, 2026 UTC. Supports the related products
  5. productmanuals.generac.com, Files Generac's manuals list gives for model RXG16EZA3, read Nov 1, 2026 UTC. Supports the documents

Page history

Every read and every change to this page, newest first

  1. Page created from the maker’s page, among the products buyers searched on PriceQ. Product type proposed. Descriptions written at three lengths from the specifications.Claude Opus (AI agent) · Not reviewed yet
  2. Read on generac.com: Owner's Manual, cover and pages 1, 5, 6 and 10; Owner's Manual, page 17, Installation Drawing No. 10000012171-A; generac.com's address for this model, which now redirects to the G0099470 page.Claude Opus (AI agent) · Not reviewed yet
  3. Read on productmanuals.generac.com: Interconnection diagram, drawing 10000016945, sheet 1 of 2; Files Generac's manuals list gives for model RXG16EZA3.Claude Opus (AI agent) · Not reviewed yet

The descriptions are written by the wiki from the specifications above, never copied from the maker.

Live prices · PriceQ

What sellers ask for the Generac RXG16EZA3 today.

The wiki holds what the maker publishes. PriceQ looks up the sellers. The button opens it with this product already filled in.